Product specification guides

Can a 4.5 m wide awning project 4 m?

JYAVENRO

QHB lists 4 m projection from 4.5 m width. QHC lists a minimum of 4.55 m for the same projection, so a strict 4.5 m limit does not meet its table. The 50 mm difference matters.

Photograph from the supplied brochure: QHC full-cassette awning

Keep measurements in millimetres

Write 4500 mm and 4000 mm in the request, marking which is width and which is projection. Avoid rounding an installation opening to the nearest half metre when checking a minimum-width row.

Check the frame envelope

Ask whether the quoted width includes end caps and the full cassette. Show adjacent walls and pipes. Do not assume the required extra 50 mm can be taken from the bracket or fabric width.

Use a measured alternative

If the wall cannot take 4550 mm, discuss QHB or a reduced projection using the appropriate model table. Change the specification explicitly rather than approving a drawing that quietly changes the requested coverage.

Specifications behind this guide

QHB full-cassette awning

Listed width range
2-6 m
Listed projection range
1.5-4 m
QHB: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52
22.5
2.53
33.5
3.54
44.5

A 4 m projection requires at least 4.5 m width. Arm lighting is optional; select fabric, manual or motorised operation, and mounting brackets with your order.

See model details

QHC full-cassette awning

Listed width range
2.05-7 m
Listed projection range
1.5-4 m
Cassette section
247 × 155 mm
Arm wall thickness
3.5 mm
QHC: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52.05
22.55
2.53.05
33.55
3.54.05
44.55

The 7 × 4 m configuration uses three arms and three wall brackets. Confirm LED colour temperature when ordering.

See model details

Before you approve the order

  • Confirm model, overall width, projection and the drawing revision in one written order.
  • Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
  • Agree delivery contents, site-work responsibilities, operating instructions and the service contact.

Good questions. Clear answers.

Can QHC be rounded down to 4.5 m?

No. Use the 4.55 m minimum shown for 4 m projection unless a separately approved model specification establishes otherwise.

Further reading

Original brochure: QHB · Pages 2Original brochure: QHC · Pages 2, 10, 11, 15

Discuss your configuration

Discuss your configurationCompare all brochure specificationsExplore installation references

Continue exploring

Let’s make room
for the outdoors.

Tell us about your space. Start with an idea, a few measurements, or simply a question.

Plan your space