Product specification guides

Can a 4.5 m wide awning project 4 m?

JYAVENRO

QHB lists 4 m projection from 4.5 m width. QHC lists a minimum of 4.55 m for the same projection, so a strict 4.5 m limit does not meet its table. The 50 mm difference matters.

Photograph from the supplied brochure: QHC full-cassette awning

Use exact measurements

Write 4500 mm and 4000 mm in the request, marking which is width and which is projection. Avoid rounding an installation opening to the nearest half metre when checking a minimum-width row.

Check the full outside dimensions

Ask whether the quoted width includes end caps and the full cassette. Show adjacent walls and pipes. Do not assume the required extra 50 mm can be taken from the bracket or fabric width.

If the first option does not fit

If the wall cannot take 4550 mm, discuss QHB or a reduced projection using the appropriate model table. Change the specification explicitly rather than approving a drawing that quietly changes the requested coverage.

Treat the 50 mm difference as a real dimension

At 4 m projection, the current minimum width is 4.5 m for QHB and 4.55 m for QHC. If the available overall width is strictly 4.5 m, QHC does not meet that table entry. Do not assume a measurement tolerance can cover the difference. Recheck what the site measurement includes and ask for an alternative combination if necessary, keeping the requested shade depth visible in the comparison.

Check the brackets within the available span

A product dimension fitting between two walls does not establish that its bracket locations have suitable support. Show the proposed fixing positions and any window openings behind them. If a model change moves those positions, review the mounting plan again. Keep the visible cassette size and the structural fixing area as separate checks rather than treating them as one measurement.

Do not hide a dimensional shortfall in rounding

When available wall width is close to a model’s minimum, the difference must remain explicit in the order discussion. Compare the exact table entry with the finished wall measurement and adjacent clearances. Do not absorb the shortfall into a vague installation tolerance. If another model or a shorter projection is proposed, show the resulting coverage on the plan so the customer understands what is gained or lost before accepting the substitution.

Turn measurements into an installation brief

Record three different things on the drawing: the available space, the outside dimensions of the product and the clear space you want to use underneath. They are not interchangeable. Choose a fixed reference, such as the finished wall face, and use it for every measurement. Include a side elevation showing the highest and lowest points, door movement and the proposed fixing level. Ask the supplier to mark any allowance that changes the usable opening. Resolve a discrepancy on the drawing before accepting a revised quotation; an unexplained change of a few centimetres can affect the entire layout.

Specifications behind this guide

QHB full-cassette awning

Listed width range
2-6 m
Listed projection range
1.5-4 m
QHB: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52
22.5
2.53
33.5
3.54
44.5

A 4 m projection requires at least 4.5 m width. Arm lighting is optional; select fabric, manual or motorised operation, and mounting brackets with your order.

See model details

QHC full-cassette awning

Listed width range
2.05-7 m
Listed projection range
1.5-4 m
Cassette section
247 × 155 mm
Arm wall thickness
3.5 mm
QHC: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52.05
22.55
2.53.05
33.55
3.54.05
44.55

The 7 × 4 m configuration uses three arms and three wall brackets. Confirm LED colour temperature when ordering.

See model details

Before you approve the order

  • Confirm model, overall width, projection and the drawing revision in one written order.
  • Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
  • Agree delivery contents, site-work responsibilities, operating instructions and the service contact.

Frequently asked questions

Can QHC be rounded down to 4.5 m?

No. Use the 4.55 m minimum shown for 4 m projection unless a separately approved model specification establishes otherwise.

Discuss your configuration

Discuss your configurationCompare all brochure specificationsExplore installation references

Continue exploring

Let’s plan your
outdoor space.

Tell us about your space. Start with an idea, a few measurements, or simply a question.

Discuss your project