QHB lists 4 m projection from 4.5 m width. QHC lists a minimum of 4.55 m for the same projection, so a strict 4.5 m limit does not meet its table. The 50 mm difference matters.

Use exact measurements
Write 4500 mm and 4000 mm in the request, marking which is width and which is projection. Avoid rounding an installation opening to the nearest half metre when checking a minimum-width row.
Check the full outside dimensions
Ask whether the quoted width includes end caps and the full cassette. Show adjacent walls and pipes. Do not assume the required extra 50 mm can be taken from the bracket or fabric width.
If the first option does not fit
If the wall cannot take 4550 mm, discuss QHB or a reduced projection using the appropriate model table. Change the specification explicitly rather than approving a drawing that quietly changes the requested coverage.
Treat the 50 mm difference as a real dimension
At 4 m projection, the current minimum width is 4.5 m for QHB and 4.55 m for QHC. If the available overall width is strictly 4.5 m, QHC does not meet that table entry. Do not assume a measurement tolerance can cover the difference. Recheck what the site measurement includes and ask for an alternative combination if necessary, keeping the requested shade depth visible in the comparison.
Check the brackets within the available span
A product dimension fitting between two walls does not establish that its bracket locations have suitable support. Show the proposed fixing positions and any window openings behind them. If a model change moves those positions, review the mounting plan again. Keep the visible cassette size and the structural fixing area as separate checks rather than treating them as one measurement.
Do not hide a dimensional shortfall in rounding
When available wall width is close to a model’s minimum, the difference must remain explicit in the order discussion. Compare the exact table entry with the finished wall measurement and adjacent clearances. Do not absorb the shortfall into a vague installation tolerance. If another model or a shorter projection is proposed, show the resulting coverage on the plan so the customer understands what is gained or lost before accepting the substitution.
Turn measurements into an installation brief
Record three different things on the drawing: the available space, the outside dimensions of the product and the clear space you want to use underneath. They are not interchangeable. Choose a fixed reference, such as the finished wall face, and use it for every measurement. Include a side elevation showing the highest and lowest points, door movement and the proposed fixing level. Ask the supplier to mark any allowance that changes the usable opening. Resolve a discrepancy on the drawing before accepting a revised quotation; an unexplained change of a few centimetres can affect the entire layout.
Specifications behind this guide
QHB full-cassette awning
- Listed width range
- 2-6 m
- Listed projection range
- 1.5-4 m
| Projection (m) | Minimum width (m) |
|---|---|
| 1.5 | 2 |
| 2 | 2.5 |
| 2.5 | 3 |
| 3 | 3.5 |
| 3.5 | 4 |
| 4 | 4.5 |
A 4 m projection requires at least 4.5 m width. Arm lighting is optional; select fabric, manual or motorised operation, and mounting brackets with your order.
See model detailsQHC full-cassette awning
- Listed width range
- 2.05-7 m
- Listed projection range
- 1.5-4 m
- Cassette section
- 247 × 155 mm
- Arm wall thickness
- 3.5 mm
| Projection (m) | Minimum width (m) |
|---|---|
| 1.5 | 2.05 |
| 2 | 2.55 |
| 2.5 | 3.05 |
| 3 | 3.55 |
| 3.5 | 4.05 |
| 4 | 4.55 |
The 7 × 4 m configuration uses three arms and three wall brackets. Confirm LED colour temperature when ordering.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.