The QHC brochure gives the cassette profile as 247 × 155 mm. You will need extra room for the brackets, the awning to open and access for maintenance. Check these spaces on the installation drawing rather than using the cassette size alone.

Use the section in the correct orientation
Ask for the dimensioned side view instead of assuming which number applies to the available recess. Include the bracket and wall line when comparing the assembly with beams or soffits.
Check movement and maintenance
A cassette that fits when closed may still conflict with an opening door or service cover. Request the deployed arm path and a practical route to inspect motor and electrical connections.
Allow room for the whole installation
Add mounting offsets and clearances to the order drawing. Do not instruct an installer to cut a 247 × 155 mm recess solely from the brochure section value.
Build up the space from several parts
Begin with the stated 247 × 155 mm cassette section, then add the actual bracket position and the space needed for wiring and access. Check which dimension is vertical in the proposed mounting orientation. A recess that matches the cassette profile exactly may still be unsuitable because the bracket or service cover needs extra room. Ask for an installed section drawing, not only a catalogue image of the box.
Check both ends of a recessed installation
Record the nearest wall return, pipe or light at each end. The motor connection and service access may make the two ends different, so do not mirror one side automatically. Confirm how the installed unit will be reached later. A neat front view should not depend on permanently sealing the parts that need access.
Draw the service space as well as the housing
Ask for a side view showing the cassette, brackets and surrounding finished surfaces. Then ask how the end covers and drive can be reached for service, and whether the proposed recess obstructs removal. Keep the published housing section separate from the supplier-confirmed installation envelope. If a light fitting, downpipe or opening door occupies that space, show it on the same drawing and resolve the conflict before manufacture. Do not add an arbitrary allowance: obtain the arrangement for the actual model and mounting method.
Turn measurements into an installation brief
Record three different things on the drawing: the available space, the outside dimensions of the product and the clear space you want to use underneath. They are not interchangeable. Choose a fixed reference, such as the finished wall face, and use it for every measurement. Include a side elevation showing the highest and lowest points, door movement and the proposed fixing level. Ask the supplier to mark any allowance that changes the usable opening. Resolve a discrepancy on the drawing before accepting a revised quotation; an unexplained change of a few centimetres can affect the entire layout.
Specifications behind this guide
QHC full-cassette awning
- Listed width range
- 2.05-7 m
- Listed projection range
- 1.5-4 m
- Cassette section
- 247 × 155 mm
- Arm wall thickness
- 3.5 mm
| Projection (m) | Minimum width (m) |
|---|---|
| 1.5 | 2.05 |
| 2 | 2.55 |
| 2.5 | 3.05 |
| 3 | 3.55 |
| 3.5 | 4.05 |
| 4 | 4.55 |
The 7 × 4 m configuration uses three arms and three wall brackets. Confirm LED colour temperature when ordering.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.
- Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
- Agree delivery contents, site-work responsibilities, operating instructions and the service contact.