T1200 lists width ≤8 m, projection ≤12 m and area ≤72 m². These limits apply together. Multiplying the two largest dimensions gives 96 m², which exceeds the brochure area limit.

Test the area before requesting a quote
As preliminary arithmetic, 8 × 9 m and 6 × 12 m both equal 72 m²; 8 × 12 m equals 96 m². The first two pass only the stated dimensional screening, not final engineering approval.
Treat a larger footprint as a layout problem
For a larger terrace, ask for a multi-module proposal with explicit bay widths, shared supports and drainage. Dividing area on paper alone does not establish a workable structural arrangement.
Include the agreed dimensions in your order
Record the chosen module dimensions and the source page with the approved drawing. If a supplier offers a configuration outside the brochure, request its own supporting specification rather than silently overriding the limit.
Check the three limits with actual examples
A 6 × 12 m rectangle has an area of 72 m² and stays within the listed width and projection limits. An 8 × 9 m rectangle also totals 72 m². An 8 × 12 m rectangle totals 96 m², so it fails the area condition even though each edge matches a stated maximum. Passing this arithmetic is only an initial size check; it does not establish the supports, connections or suitability for the site.
Treat a larger terrace as a new layout
If the required area exceeds one module, ask for a proposed module plan showing supports and the joints between roofs. Include gutter routes and whether sections operate together or separately. Dividing an area on paper is not enough; the meeting edges and fixing positions also need a solution. Keep the desired seating layout visible while considering where extra structure can go.
Keep an area limit separate from a project total
A stated area limit does not mean every rectangle with that area is an equivalent roof. Check width, length, support and orientation together using the supplied table. For a larger project, identify how many modules are proposed and where their junctions occur. Each junction may affect the visible roof pattern, support layout and drainage coordination. Ask for the module schedule rather than accepting the total area as sufficient evidence of a workable arrangement.
Coordinate the roof with the supporting structure
A product outline is only one part of the installation. Show how the roof loads will pass into the wall, posts or supporting frame, and agree who will check the existing structure. The final arrangement should also show how water leaves the roof and where cables enter without obstructing a moving component. If supports or drainage change, update the roof drawing as well as the site plan. Keep fabrication dimensions separate from preliminary measurements until the interfaces have been agreed; otherwise a correctly manufactured product can still arrive with an unsuitable connection to the building.
Specifications behind this guide
T-series retractable folding roofs
- Projection up to 7 m
- T700
- Projection up to 9 m
- T900
- Projection up to 12 m; area ≤72 m²
- T1200
| Model | Width limit (m) | Projection limit (m) | Rail section |
|---|---|---|---|
| T700 | 8 | 7 | 130 × 70 × 2.5 mm |
| T900 | 8 | 9 | 170 × 98 × 2.5 mm |
| T1200 | 8 | 12 | 200 × 130 × 2.5 mm |
T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.
- Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
- Agree delivery contents, site-work responsibilities, operating instructions and the service contact.