The supplied brochure lists maximum projections of 7 m, 9 m and 12 m for T700, T900 and T1200. Selection also depends on width, area, profiles and the actual installation arrangement.

Start with required depth
An 8 m projection exceeds the listed T700 limit, while T900 may remain a candidate. Passing that first check does not approve the whole design; evaluate width and site details next.
Keep each profile set together
The three series have different rail sections; T1200 also lists larger posts and gutters. Compare a complete model specification instead of replacing one rail while keeping unconfirmed smaller components.
Check width, projection and area together
T1200 includes a 72 m² area limit alongside width and projection limits. Ask for a confirmed module layout when the intended footprint does not fit all three conditions at once.
Start with the required reach, then check the rest
The stated maximum projections of 7 m, 9 m and 12 m distinguish T700, T900 and T1200, but they are not complete design envelopes. A proposal must also fit the applicable width and area limits and the intended supporting structure. For example, a long narrow terrace and a wide shallow terrace with equal area can lead to different rail arrangements. Give the direction of travel on the plan instead of supplying only a square-metre figure.
Compare the full frame in the quotation
Ask the supplier to identify the rails, posts and gutter for the proposed model, and whether the supporting steelwork is included or supplied separately. A larger rail section does not by itself establish the finished roof’s wind performance. Compare the model-specific information and installation arrangement, then choose the configuration that fits the site rather than automatically selecting the largest model number.
Choose using the proposed bay layout
Compare each series against the width, travel direction and support arrangement of the proposed bay. A maximum area alone cannot describe all three. If one series requires additional bays, show the intermediate rails and posts on the same drawing before comparing price. Also identify the location of the fabric stack and the route for water discharge. The suitable option is the one that meets the documented configuration and the site layout together.
Coordinate the roof with the supporting structure
A product outline is only one part of the installation. Show how the roof loads will pass into the wall, posts or supporting frame, and agree who will check the existing structure. The final arrangement should also show how water leaves the roof and where cables enter without obstructing a moving component. If supports or drainage change, update the roof drawing as well as the site plan. Keep fabrication dimensions separate from preliminary measurements until the interfaces have been agreed; otherwise a correctly manufactured product can still arrive with an unsuitable connection to the building.
Specifications behind this guide
T-series retractable folding roofs
- Projection up to 7 m
- T700
- Projection up to 9 m
- T900
- Projection up to 12 m; area ≤72 m²
- T1200
| Model | Width limit (m) | Projection limit (m) | Rail section |
|---|---|---|---|
| T700 | 8 | 7 | 130 × 70 × 2.5 mm |
| T900 | 8 | 9 | 170 × 98 × 2.5 mm |
| T1200 | 8 | 12 | 200 × 130 × 2.5 mm |
T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.
- Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
- Agree delivery contents, site-work responsibilities, operating instructions and the service contact.