The supplied brochure lists maximum projections of 7 m, 9 m and 12 m for T700, T900 and T1200. Selection also depends on width, area, profiles and the actual installation arrangement.

Start with required depth
An 8 m projection exceeds the listed T700 limit, while T900 may remain a candidate. Passing that first check does not approve the whole design; evaluate width and site details next.
Keep each profile set together
The three series have different rail sections; T1200 also lists larger posts and gutters. Compare a complete model specification instead of replacing one rail while keeping unconfirmed smaller components.
Apply all limits together
T1200 includes a 72 m² area limit alongside width and projection limits. Ask for a confirmed module layout when the intended footprint does not fit all three conditions at once.
Specifications behind this guide
T-series retractable folding roofs
- Projection up to 7 m
- T700
- Projection up to 9 m
- T900
- Projection up to 12 m; area ≤72 m²
- T1200
| Model | Width limit (m) | Projection limit (m) | Rail section |
|---|---|---|---|
| T700 | 8 | 7 | 130 × 70 × 2.5 mm |
| T900 | 8 | 9 | 170 × 98 × 2.5 mm |
| T1200 | 8 | 12 | 200 × 130 × 2.5 mm |
T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.
- Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.