An 8 m width and 9 m projection sit within T900’s listed dimensional limits. They also meet T1200’s width and projection limits, with the resulting 72 m² at its area ceiling. Compare the profiles and installation layout next.

Compare actual profile dimensions
T900 lists a 170 × 98 × 2.5 mm rail; T1200 lists 200 × 130 × 2.5 mm. Their posts and gutters also differ. Account for the visible section and available connection space, not just the series name.
A larger profile is not a rating
Do not infer a universal wind or load rating from section dimensions. Ask for evidence matching the ordered size, support arrangement and installation conditions if project performance requirements must be demonstrated.
Compare what is supplied
Use the same fabric, controls, finish and delivery basis for both quotations. List support work and drainage connections separately. This makes a cost difference easier to relate to the actual configuration.
Compare complete layouts
An eight-by-nine-metre layout has an area of 72 m². When the nine-metre side is the projection, it falls within the stated T900 dimensions and reaches the T1200 area limit. Those numbers alone do not decide which system fits the site. Compare the proposed rails, posts, gutters and drive arrangement for the same orientation and furniture layout, using the actual configuration offered for each system.
Look beyond the profile size
A larger profile changes the appearance and connection details; it does not by itself prove a better result for every terrace. Review support positions, the fabric package when open and access for future servicing. If one layout needs a post where people normally walk, resolve that issue on the plan. A clear comparison should explain what changes in the finished space as well as in the price.
Compare alternative module plans on the same site
An eight-by-nine footprint can be divided or oriented in more than one way. Request a separate plan for each proposed series, showing all intermediate rails and supports. Compare usable space, collection zones and operating groups as well as the total roof area. If a proposal needs a different module count, make that difference visible in the quotation. A model comparison is incomplete when the layouts behind the two prices are not shown.
Coordinate the roof with the supporting structure
A product outline is only one part of the installation. Show how the roof loads will pass into the wall, posts or supporting frame, and agree who will check the existing structure. The final arrangement should also show how water leaves the roof and where cables enter without obstructing a moving component. If supports or drainage change, update the roof drawing as well as the site plan. Keep fabrication dimensions separate from preliminary measurements until the interfaces have been agreed; otherwise a correctly manufactured product can still arrive with an unsuitable connection to the building.
Specifications behind this guide
T-series retractable folding roofs
- Projection up to 7 m
- T700
- Projection up to 9 m
- T900
- Projection up to 12 m; area ≤72 m²
- T1200
| Model | Width limit (m) | Projection limit (m) | Rail section |
|---|---|---|---|
| T700 | 8 | 7 | 130 × 70 × 2.5 mm |
| T900 | 8 | 9 | 170 × 98 × 2.5 mm |
| T1200 | 8 | 12 | 200 × 130 × 2.5 mm |
T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.
- Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
- Agree delivery contents, site-work responsibilities, operating instructions and the service contact.