With 6 m width and 12 m projection, the area is 72 m². Those numbers meet T1200’s listed width, projection and area limits together. This is a preliminary table check, not approval of the supporting structure or installation.

State which side is projection
Write the rail-travel direction on the plan. A 6 m width with 12 m projection is different from 12 m width with 6 m projection; the latter exceeds the listed 8 m width limit for a single T1200 unit.
Keep all limits in the order
Specify width ≤8 m, projection ≤12 m and area ≤72 m² together. Because the example reaches the area limit, an increase in either dimension needs another calculation rather than a casual rounding adjustment.
Complete the site layout
Supply support positions, rear and front heights, drainage outlets and the fabric parking location. These define how the selected roof fits the building and are separate from passing the size table.
Label width and travel direction
A layout six metres wide with twelve metres of projection reaches 72 m². It sits within the stated T1200 width, projection and area limits, but that is only the starting point for a project layout. Rotating those dimensions would create a twelve-metre width, beyond the stated eight-metre width limit. Put arrows and dimension labels on the drawing so the intended orientation is unmistakable.
Plan the retracted position
Show the fabric stack, supports and gutter on the same plan as the furniture. Check the view and headroom beneath the retracted fabric, and retain access to the drive and guides. On a long roof, the retracted end can become a very different space from the open end. Decide which activities belong below each before finalising the layout.
Specify the direction as well as the rectangle
Label which dimension follows the guides and which runs across the roof. The same rectangle rotated on a plan can imply a different movement and support arrangement. Ask the supplier to identify the proposed module boundary, fabric collection end and drainage direction on one drawing. Keep the site’s usable clearances visible beside the product dimensions. This makes it possible to compare the documented proposal rather than treating an area calculation as an installation plan.
Coordinate the roof with the supporting structure
A product outline is only one part of the installation. Show how the roof loads will pass into the wall, posts or supporting frame, and agree who will check the existing structure. The final arrangement should also show how water leaves the roof and where cables enter without obstructing a moving component. If supports or drainage change, update the roof drawing as well as the site plan. Keep fabrication dimensions separate from preliminary measurements until the interfaces have been agreed; otherwise a correctly manufactured product can still arrive with an unsuitable connection to the building.
Specifications behind this guide
T-series retractable folding roofs
- Projection up to 7 m
- T700
- Projection up to 9 m
- T900
- Projection up to 12 m; area ≤72 m²
- T1200
| Model | Width limit (m) | Projection limit (m) | Rail section |
|---|---|---|---|
| T700 | 8 | 7 | 130 × 70 × 2.5 mm |
| T900 | 8 | 9 | 170 × 98 × 2.5 mm |
| T1200 | 8 | 12 | 200 × 130 × 2.5 mm |
T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.
- Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
- Agree delivery contents, site-work responsibilities, operating instructions and the service contact.
