With 6 m width and 12 m projection, the area is 72 m². Those numbers meet T1200’s listed width, projection and area limits together. This is a preliminary table check, not approval of the supporting structure or installation.

State which side is projection
Write the rail-travel direction on the plan. A 6 m width with 12 m projection is different from 12 m width with 6 m projection; the latter exceeds the listed 8 m width limit for a single T1200 unit.
Keep all limits in the order
Specify width ≤8 m, projection ≤12 m and area ≤72 m² together. Because the example reaches the area limit, an increase in either dimension needs another calculation rather than a casual rounding adjustment.
Complete the site layout
Supply support positions, rear and front heights, drainage outlets and the fabric parking location. These define how the selected roof fits the building and are separate from passing the size table.
Specifications behind this guide
T-series retractable folding roofs
- Projection up to 7 m
- T700
- Projection up to 9 m
- T900
- Projection up to 12 m; area ≤72 m²
- T1200
| Model | Width limit (m) | Projection limit (m) | Rail section |
|---|---|---|---|
| T700 | 8 | 7 | 130 × 70 × 2.5 mm |
| T900 | 8 | 9 | 170 × 98 × 2.5 mm |
| T1200 | 8 | 12 | 200 × 130 × 2.5 mm |
T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.
- Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
- Agree delivery contents, site-work responsibilities, operating instructions and the service contact.