Adjacent cassette awnings can divide a frontage into separate units. A coordinated folding-roof layout addresses support, fabric travel and drainage together. Choose by the required coverage and junction detail, not just total width.

Draw the junction
Show the gap between units, the front edges when extended and any difference in mounting height. Two neighbouring fabrics do not automatically form a sealed roof joint; identify what is expected beneath that gap.
Define independent operation
Different seating areas may benefit from separate controls. Write down which units should move together and which need individual use. A matched fabric colour does not establish compatible motors or grouped controls.
Compare the whole layout
Compare support work, unit count, junction treatment, controls and installation in one schedule. Where uninterrupted dining coverage is important, request a roof plan showing each bay and drainage route before choosing by price.
Compare what happens at the centre line
Two cassette awnings can shade separate parts of a frontage, but their meeting edges are not automatically a sealed roof joint. Draw the gap, front bars and movement of both units. A coordinated folding roof uses a different support and drainage arrangement, which also needs to be designed. If a dining table sits directly below the junction, discuss that position explicitly rather than judging the choice only by total covered width.
Choose independent or shared use deliberately
Separate awnings can suit two seating zones with different opening times. A shared roof may suit a terrace intended to read as one space. Compare controls, supports and service access in both proposals. The cheaper-looking option may omit the junction or electrical work that the other proposal includes, so compare the complete arrangement around the same furniture plan.
Compare the joint between neighbouring units
Several cassette awnings placed side by side remain separate assemblies. Ask how their edges align and what happens between them in each operating position. A continuous-looking front elevation does not prove continuous weather coverage. Compare that arrangement with a framed roof using the same seating plan and support constraints. Include control independence and access for servicing one unit without dismantling the neighbour when deciding which arrangement is more useful.
Check the complete operating sequence
Review the proposal in the positions people will actually use: fully open, partly open and closed. Check what remains in the opening, where moving parts travel and whether someone can still reach the controls. Agree who demonstrates normal operation at handover and how the owner obtains the instructions for the supplied motor and accessories. A useful demonstration includes stopping midway and operating each zone separately. Record any limitation against the relevant component rather than relying on a general promise that the whole installation is automatic or suitable for every weather condition.
Specifications behind this guide
QHA full-cassette awning
- Listed width range
- 2-6 m
- Projection in size table
- 1.5-3.5 m
| Projection (m) | Minimum width (m) |
|---|---|
| 1.5 | 2 |
| 2 | 3 |
| 2.5 | 3.5 |
| 3 | 4 |
| 3.5 | 4.5 |
The 3.5 m projection requires a width of at least 4.5 m and confirmation of availability. Ceiling mounting requires custom brackets.
See model detailsQHB full-cassette awning
- Listed width range
- 2-6 m
- Listed projection range
- 1.5-4 m
| Projection (m) | Minimum width (m) |
|---|---|
| 1.5 | 2 |
| 2 | 2.5 |
| 2.5 | 3 |
| 3 | 3.5 |
| 3.5 | 4 |
| 4 | 4.5 |
A 4 m projection requires at least 4.5 m width. Arm lighting is optional; select fabric, manual or motorised operation, and mounting brackets with your order.
See model detailsQHC full-cassette awning
- Listed width range
- 2.05-7 m
- Listed projection range
- 1.5-4 m
- Cassette section
- 247 × 155 mm
- Arm wall thickness
- 3.5 mm
| Projection (m) | Minimum width (m) |
|---|---|
| 1.5 | 2.05 |
| 2 | 2.55 |
| 2.5 | 3.05 |
| 3 | 3.55 |
| 3.5 | 4.05 |
| 4 | 4.55 |
The 7 × 4 m configuration uses three arms and three wall brackets. Confirm LED colour temperature when ordering.
See model detailsT-series retractable folding roofs
- Projection up to 7 m
- T700
- Projection up to 9 m
- T900
- Projection up to 12 m; area ≤72 m²
- T1200
| Model | Width limit (m) | Projection limit (m) | Rail section |
|---|---|---|---|
| T700 | 8 | 7 | 130 × 70 × 2.5 mm |
| T900 | 8 | 9 | 170 × 98 × 2.5 mm |
| T1200 | 8 | 12 | 200 × 130 × 2.5 mm |
T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.
- Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.