Product specification guides

Wholesale awning orders: build a model and packing schedule

JYAVENRO

For a mixed wholesale order, give every unit a unique line reference and approved configuration. Match model, dimensions, fabric, controls and installation parts before discussing packing or a combined shipment.

Photograph from the supplied brochure: QHA full-cassette awning

Use one row per configuration

Two awnings of equal width may require different projection, bracket type or motor package. Record quantity only after those fields match; otherwise a single total can conceal incompatible parts.

Link packing marks to installation units

Request package dimensions and weights from the confirmed packing plan, not from product width alone. Use unit references on loose hardware boxes so installers can match parts without opening every crate.

Control substitutions and repeat orders

Archive drawing revision, colour sample and motor references for each order line. Require written acceptance before substituting profiles, fabrics or controls in a repeat batch, even when the trade name stays unchanged.

Give each finished unit a clear identity

Use an order line for each distinct combination of model, width, projection, fabric, frame finish and control. Repeat the same reference on the drawing, packing list and destination label. If two units look similar but have different dimensions, keep them separately identifiable. This helps the receiving team send the correct components to each installation without relying on someone recognising the product by appearance.

Check the order after any substitution

A change to a remote, bracket or fabric can affect more than one line in a mixed order. Record which units use the new version and whether any installation or operating information changes. Send the revised list to the people packing and receiving the goods. Avoid mixing old and new labels, particularly when part of the order has already shipped.

Make package identification useful at the destination

A package number should lead the receiver to the relevant model, dimensions and destination, not only to a shipping count. Identify separately packed brackets, controls and accessories. If several units look alike but differ in projection or fabric, mark the distinction on both the schedule and labels. Ask for the final packing list before dispatch and check that any late order changes have reached the packing team as well as production.

Compare quotations for the same specification

Give each supplier the same drawing revision and a dated list of options. Ask them to distinguish included items, alternatives and work to be arranged on site. When a price changes, request a short description of what changed with it: dimensions, fabric, drive, mounting parts, packing or delivery scope. Keep decisions in one approved schedule rather than scattered across messages. Before payment for production, compare that schedule with the final drawing and order acknowledgement. This creates a usable record for receiving the goods and resolving a missing or substituted component.

Specifications behind this guide

QHA full-cassette awning

Listed width range
2-6 m
Projection in size table
1.5-3.5 m
QHA: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52
23
2.53.5
34
3.54.5

The 3.5 m projection requires a width of at least 4.5 m and confirmation of availability. Ceiling mounting requires custom brackets.

See model details

QHB full-cassette awning

Listed width range
2-6 m
Listed projection range
1.5-4 m
QHB: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52
22.5
2.53
33.5
3.54
44.5

A 4 m projection requires at least 4.5 m width. Arm lighting is optional; select fabric, manual or motorised operation, and mounting brackets with your order.

See model details

QHC full-cassette awning

Listed width range
2.05-7 m
Listed projection range
1.5-4 m
Cassette section
247 × 155 mm
Arm wall thickness
3.5 mm
QHC: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52.05
22.55
2.53.05
33.55
3.54.05
44.55

The 7 × 4 m configuration uses three arms and three wall brackets. Confirm LED colour temperature when ordering.

See model details

T-series retractable folding roofs

Projection up to 7 m
T700
Projection up to 9 m
T900
Projection up to 12 m; area ≤72 m²
T1200
T-series retractable folding roofs
ModelWidth limit (m)Projection limit (m)Rail section
T70087130 × 70 × 2.5 mm
T90089170 × 98 × 2.5 mm
T1200812200 × 130 × 2.5 mm

T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.

See model details

Before you approve the order

  • Confirm model, overall width, projection and the drawing revision in one written order.
  • Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
  • Agree delivery contents, site-work responsibilities, operating instructions and the service contact.

Frequently asked questions

Can the brochure determine MOQ and delivery time?

The supplied technical references do not establish a universal MOQ or lead time. Request both against the actual mixed order and approved configuration.

Discuss your configuration

Discuss your configurationCompare all brochure specificationsExplore installation references

Continue exploring

Let’s plan your
outdoor space.

Tell us about your space. Start with an idea, a few measurements, or simply a question.

Discuss your project