Send a front view, side view, fixing-surface close-up and a sketch with width, projection and height. Add the installation location and quantity. Clear site information helps separate product selection from unanswered installation questions.

Photograph the boundaries
Include both ends of the wall, windows above and the ground beneath. A close-up of only the intended roof area hides downpipes, door swings and access restrictions. Add a side photograph showing the proposed projection.
Mark measured dimensions
Use one unit, preferably millimetres, and name each dimension. For folding roofs, add front and rear heights and the intended motor side. Photographs explain the setting; they do not replace measurements or a checked fixing specification.
Keep the photos and measurements together
Send the location, intended use, quantity and preferred product with the photos. Keep the same project name when following up by WhatsApp, WeChat or email. Record revised dimensions so an older image is not mistaken for the final order.
Explore this topic: Your outdoor project planning checklist
Make the site easy to understand
Start with a wide photograph showing the whole frontage, then add a side view and close-ups of the proposed fixing area. Number the photographs and mark matching positions on a simple sketch. Write measured dimensions with their units and arrows showing the intended projection. Photos explain obstacles and context; they do not reliably establish measurements, hidden wall construction or the condition of concealed supports.
Send one coherent enquiry
Send the location, quantity, preferred product and numbered site images together, and mention whether the main use is dining, seating or a commercial terrace. If you have not chosen a model, describe the space instead. A single consistent set of dimensions is more useful than several messages containing different estimates. Keep a copy of the agreed drawing so later changes can refer to the same layout.
Make each photograph answer a question
Send one wide view to explain the location, then closer views of the fixing surface, obstructions and proposed power entry. Add a simple labelled sketch so the supplier knows which photograph shows each side. Avoid relying on perspective to communicate size; pair the image with a measured dimension and a clear reference point. Include the space below the proposed awning, because furniture, doors and the receiving ground level affect the layout as much as the façade does.
Turn measurements into an installation brief
Record three different things on the drawing: the available space, the outside dimensions of the product and the clear space you want to use underneath. They are not interchangeable. Choose a fixed reference, such as the finished wall face, and use it for every measurement. Include a side elevation showing the highest and lowest points, door movement and the proposed fixing level. Ask the supplier to mark any allowance that changes the usable opening. Resolve a discrepancy on the drawing before accepting a revised quotation; an unexplained change of a few centimetres can affect the entire layout.
Specifications behind this guide
QHA full-cassette awning
- Listed width range
- 2-6 m
- Projection in size table
- 1.5-3.5 m
| Projection (m) | Minimum width (m) |
|---|---|
| 1.5 | 2 |
| 2 | 3 |
| 2.5 | 3.5 |
| 3 | 4 |
| 3.5 | 4.5 |
The 3.5 m projection requires a width of at least 4.5 m and confirmation of availability. Ceiling mounting requires custom brackets.
See model detailsQHB full-cassette awning
- Listed width range
- 2-6 m
- Listed projection range
- 1.5-4 m
| Projection (m) | Minimum width (m) |
|---|---|
| 1.5 | 2 |
| 2 | 2.5 |
| 2.5 | 3 |
| 3 | 3.5 |
| 3.5 | 4 |
| 4 | 4.5 |
A 4 m projection requires at least 4.5 m width. Arm lighting is optional; select fabric, manual or motorised operation, and mounting brackets with your order.
See model detailsQHC full-cassette awning
- Listed width range
- 2.05-7 m
- Listed projection range
- 1.5-4 m
- Cassette section
- 247 × 155 mm
- Arm wall thickness
- 3.5 mm
| Projection (m) | Minimum width (m) |
|---|---|
| 1.5 | 2.05 |
| 2 | 2.55 |
| 2.5 | 3.05 |
| 3 | 3.55 |
| 3.5 | 4.05 |
| 4 | 4.55 |
The 7 × 4 m configuration uses three arms and three wall brackets. Confirm LED colour temperature when ordering.
See model detailsT-series retractable folding roofs
- Projection up to 7 m
- T700
- Projection up to 9 m
- T900
- Projection up to 12 m; area ≤72 m²
- T1200
| Model | Width limit (m) | Projection limit (m) | Rail section |
|---|---|---|---|
| T700 | 8 | 7 | 130 × 70 × 2.5 mm |
| T900 | 8 | 9 | 170 × 98 × 2.5 mm |
| T1200 | 8 | 12 | 200 × 130 × 2.5 mm |
T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.
See model detailsBefore you approve the order
- Confirm model, overall width, projection and the drawing revision in one written order.
- Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
- Agree delivery contents, site-work responsibilities, operating instructions and the service contact.