Product specification guides

Buying one custom awning: from measurements to handover

JYAVENRO

A single custom order needs the same clarity as a larger project: an agreed model, a dimensioned drawing, a defined supply scope and a handover record. Begin with the site, not a copied brochure maximum.

Photograph from the supplied brochure: QHA full-cassette awning

Build a useful enquiry pack

Send location, overall and close-up photographs, preliminary width and depth, mounting surface and preferred use. State whether you need a front-post-free cassette awning or a supported folding roof.

Approve the drawing and responsibilities

Check dimensions, mounting parts, finish, fabric and controls on one written proposal. Separately identify shipping, site preparation, installation and electrical connection so a product price is not mistaken for a complete installed price.

Keep a practical handover record

At handover, record opening and closing checks, agreed settings, supplied instructions and the service contact. Keep model and component references so future support does not depend on remembering the original sales discussion.

Review the drawing as a homeowner, not an engineer

You do not need to understand every technical symbol to check the main arrangement. Identify the house side, the front edge, the doors and the furniture. Ask which dimensions describe the outside frame and which describe usable space. If the drawing differs from the photograph you discussed, ask what changed and why. A clear explanation now is more useful than discovering after delivery that the roof opens in an unexpected direction.

Try the normal operations before the team leaves

Have the installer demonstrate normal opening, closing and any separate lighting or screen controls. Ask where the product identification and service contact are recorded. Keep a photo of the installed arrangement and the relevant instructions. If anything still needs adjustment, record the specific issue with the installer instead of trying unfamiliar settings yourself after the work is finished.

Make handover a practical demonstration

Ask the installer to demonstrate opening, stopping and closing using the controls the homeowner will keep. Identify the relevant unit if there is more than one awning, and record where instructions and service details are stored. Review how to report an unusual sound or incomplete movement without attempting an adjustment that belongs to the installer. Photographs of the finished mounting and the agreed configuration can make later service discussions much clearer.

Check the complete operating sequence

Review the proposal in the positions people will actually use: fully open, partly open and closed. Check what remains in the opening, where moving parts travel and whether someone can still reach the controls. Agree who demonstrates normal operation at handover and how the owner obtains the instructions for the supplied motor and accessories. A useful demonstration includes stopping midway and operating each zone separately. Record any limitation against the relevant component rather than relying on a general promise that the whole installation is automatic or suitable for every weather condition.

Specifications behind this guide

QHA full-cassette awning

Listed width range
2-6 m
Projection in size table
1.5-3.5 m
QHA: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52
23
2.53.5
34
3.54.5

The 3.5 m projection requires a width of at least 4.5 m and confirmation of availability. Ceiling mounting requires custom brackets.

See model details

QHB full-cassette awning

Listed width range
2-6 m
Listed projection range
1.5-4 m
QHB: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52
22.5
2.53
33.5
3.54
44.5

A 4 m projection requires at least 4.5 m width. Arm lighting is optional; select fabric, manual or motorised operation, and mounting brackets with your order.

See model details

QHC full-cassette awning

Listed width range
2.05-7 m
Listed projection range
1.5-4 m
Cassette section
247 × 155 mm
Arm wall thickness
3.5 mm
QHC: Projection (m) / Minimum width (m)
Projection (m)Minimum width (m)
1.52.05
22.55
2.53.05
33.55
3.54.05
44.55

The 7 × 4 m configuration uses three arms and three wall brackets. Confirm LED colour temperature when ordering.

See model details

T-series retractable folding roofs

Projection up to 7 m
T700
Projection up to 9 m
T900
Projection up to 12 m; area ≤72 m²
T1200
T-series retractable folding roofs
ModelWidth limit (m)Projection limit (m)Rail section
T70087130 × 70 × 2.5 mm
T90089170 × 98 × 2.5 mm
T1200812200 × 130 × 2.5 mm

T1200: width ≤8 m, projection ≤12 m and total unit area ≤72 m² must all be met. Standard PVC fabric; Sauleda available as an option.

See model details

Before you approve the order

  • Confirm model, overall width, projection and the drawing revision in one written order.
  • Match mounting parts, fabric reference, finish and controls to the quotation; document any substitution.
  • Agree delivery contents, site-work responsibilities, operating instructions and the service contact.

Frequently asked questions

Can I order from a photograph without measurements?

A photo can start the discussion but cannot define manufacturing dimensions or mounting suitability. Approve measured drawings before production.

Discuss your configuration

Discuss your configurationCompare all brochure specificationsExplore installation references

Continue exploring

Let’s plan your
outdoor space.

Tell us about your space. Start with an idea, a few measurements, or simply a question.

Discuss your project